Skip to main content

S-35710 PROGRAMMABLE WAKE-UP TIMER IC

 S-35710

PROGRAMMABLE WAKE-UP TIMER IC

The wake-up timer IC allows for intermittent system operation by periodically waking up the system. The S-35710 Series compares the timer value and the value written to the internal register, and outputs a wake-up signal (interrupt signal) when the values match each other. The timer of the S-35710 Series is a 24-bit binary-up counter. The internal register data can be set freely by users via a 2-wire serial interface. Consequently, the time before the occurrence of a wake-up signal (interrupt signal) can be set freely.


Ultra-low Power Consumption and Highly Flexible Wake-up Time Settings Facilitate Intermittent System Operation

ABLIC Inc. launched the S-35710/20 (I-Series), a wake-up timer IC with ultra-low power consumption that allows flexible wake-up time settings. This product has already been launched as a convenience timer for automotive use, but the new S-35710/20 (I-Series) timer IC was launched as a general-purpose wake-up timer IC. A wake-up timer IC is an IC that enables intermittent system operation by periodically starting up the system.

Comments

Popular posts from this blog

Advanced 1-Wire Master with Memory #DS2485

DS28E18 Setup Guide for Remote I 2 C and SPI Sensors Featuring the DS2485 It is well established that the I 2 C and SPI communication protocols are designed to be used in short-distance, intra-board communication. This application note discusses the I 2 C and SPI bus extending capabilities of the DS28E18 1-Wire ® to I 2 C/SPI Bridge with Command Sequencer. Specifically, it covers important measures for setting up a long line, e.g., 100m communication with multiple I 2 C and SPI sensors and the benefits of using this device. Introduction The I 2 C and SPI communication protocols are well known to have short bus distances that range no more than a couple meters. Although solutions currently exist for extending these ranges, they are often complex and expensive. The DS28E18 , however, is a cost-efficient bridge-chip device that demonstrates the benefits of using the 1-Wire interface to get the most range out of complex I 2 C and SPI devices such as environmental sensors,...

BERNINA CutWork Software

  https://www.bernina.com/en-029/Software-029/BERNINA-DesignWorks/BERNINA-CutWork-Software

how to programing delta plc and him for weigh controller

  how to programing delta plc and him for weigh controller To program a Delta PLC to function as a weigh controller, you need to follow these general steps: Connect the load cell: Connect the load cell to the PLC's analog input module. Make sure that the load cell is properly calibrated and that the signal is within the input range of the analog input module. Configure the analog input: Configure the analog input module in the PLC according to the load cell specifications (e.g. input range, sample rate, etc.). Convert the analog signal: In the PLC program, use an analog-to-digital (A/D) conversion function to convert the analog signal from the load cell into a digital value that can be processed by the PLC. Filter the signal: Apply signal filtering to the digital value to eliminate any noise or fluctuations in the signal. Calculate the weight: In the PLC program, use the filtered digital value to calculate the weight of the material on the scale. Display the weight: Use the PLC...